Medical QA Tools

Radiotherapy > ImRT/IGRT/Rotational

 


COMPASS
COMPASS leads you into a new era in the IMRT/IGRT pre-treatment and treatment monitoring as well as verification. It provides truly independent analysis of the accuracy of your planned treatment and the dose delivered to the patient. COMPASS is a solution to increase the precision and safety of the individual patient treatment.

A (patent pending) method using a high resolution ionization chamber transmission detector and a Linac beam model allows exact fluence determination and comparison with TPS fluence. Based on the transmission detector measurement, an advanced forward calculation algorithm subsequently reconstructs the 3D dose distribution in patient anatomy. The 3D dose distribution is then compared with the TPS. A modern set of software tools incl. DVH allows for a side by side analysis of the two data sets either cumulative or per fraction.

The solution that combines:

  • determination of dose distribution during patient treatment using a beam model, a transmission detector measurement and a fluence reconstruction
  • display of the 3D dose distribution in patient anatomy
  • comparison of measured with expected dose distributions.
   

MIMI Phantom
Test the coincidence of the isocenter prescribed by the lasers, treatment beam, and image guidance systems:

ENSURE IMAGE GUIDANCE ACCURACY
Treatment with radiation on a modern linear accelerator relies on the ability to position the patient with incredible accuracy. This is why it is critically important to verify that the systems used for positioning are all describing the same isocentric point in space as the treatment beam.

FAST, ACCURATE ALIGNMENT CHECKS
The MIMI (Multiple Imaging Modality Isocentricity) Phantom from Standard Imaging allows you to establish mechanical stability of the image guidance system by verifying the isocenter described by the MV, kV, CBCT, and other guidance systems is within accepted 1mm tolerances. This daily or weekly test can be performed in just a few minutes giving you the confidence that you can deliver the radiation prescription on target.

EASY ALIGNMENT DUE TO UNIQUE DESIGN
The MIMI Phantom incorporates five bone equivalent rods uniquely set so that four of them intersect at 90 degree angles when viewed in DRRs or a 2D projection image. The rods traverse the entire phantom making them visible in any image or slice allowing for easy 2D/2D and 3D/3D matching for fast verification of isocenter position.

 

IMSure QA Software
IMSure is designed for use as a redundant check tool for busy Radiation Therapy departments to quickly and accurately verify IMRT treatment plans and as a tool for verifying and computing simple Monitor Unit (MU) computations.

For IMRT Treatment plans, IMSure is intended for use as a secondary, independent verification tool for rapid QA of IMRT treatment plans. Using measured physical data from the linear accelerators entered into the system by a trained physicist, IMSure performs these calculations based on the patient’s data and an IMRT plan generated from the inverse treatment planning system.

INTUITIVE MU DOSE CALCULATIONS
Automate hand calculations of conventional plans or create simple plans with just a few clicks. A single screen for inputs, outputs, and field-to-field comparisons offers quick review and easy editing of plans.


ACCURATE IMRT DOSE CALCULATIONS

The patented Stanford University “3-Source Model” considers the dose from the primary photon source, the primary collimator scatter, and the flattening filter scatter resulting in extremely accurate dose calculations including those in high-gradient / low-dose regions common in IMRT.

NEW! IN-DEPTH IMRT PATIENT QA
Imported treatment planning system fluence is directly compared to independently calculated fluence in IMSure. Import patient contours and specify regions of interest for structure specific analysis. Use any of six different methods of comparison including gamma map comparisons, difference maps, a patented correlation coefficient, and histograms.

 
Ray Film Dosimetry Software

The Radiation Analyzer - RAy™ Film Dosimetry Software provides everything necessary for completing detailed IMRT QA and other frequent QA tasks. For thousands less, RAy includes features not found in other leading film dosimetry software.

3D MULTI-SLICE VOLUMETRIC FILM/PLAN ANALYSIS
Import all available slices of the treatment plan, or select as many as needed to perform plan validation. Change from one slice to the next with one click of a button.

3D RENDERED VOLUMETRIC FILM/PLAN ANALYSIS
Import the 3D dose matrix from the treatment planning system and compare directly to 3D measured data acquired with a stacked film set.

MEASURED DVH/PLANNED DVH COMPARISON
Using 3D volumetric information perform a comprehensive quantitative analysis by generating and comparing measured DVH vs. planned DVH.

CYBER-KNIFE PATIENT-SPECIFIC QA
Compare both 2D or 3D film measurements to Cyberknife planning data.  Cyberknife specific tools allow for fast registration based on tracking fiducials.

ELECTRONIC PORTAL IMAGING DEVICE (EPID)
Use EPID images or other filmless technology as input for filmless IMRT fluence validation.

MORE MEANINGFUL ANALYSIS
Add another dimension to your analysis by overlaying qualitative threshold isodose lines over quantitative information such as gamma, distance-to-agreement, percent dose difference, or DTA + % Dose Difference maps.

SAVE AND SHARE YOUR WORK
For each case, save data into one integrated .ray file so you can easily archive, retrieve, and share the complete case information with local or remote co-workers.

SAVE AND SHARE YOUR WORK
Unlimited support for the first year means answers are readily available when you need them.

 

ImRT MatriXX
The I'mRT MatriXX is the most advanced solution for fast, accurate and reliable digital IMRT verification. The PIC technology combines the advantages of vented ionization chambers using PCB technology with a state-of-the-art ASICs based electrometer.

The I'mRT MatriXX verifies individual (segment) as well as integrated (composite) IMRT fields without dead time during the data acquisition. Due to the unique electrometer solution based on ASICs technology, all 1020 vented pixel ionization chambers are read out in parallel with a minimum sampling time of only 20 ms per 2D field. As a result the Pixel Ionization Chamber Technology (PIC) used in the I´mRT MatriXX significantly reduces the time spent in dosimetric verification of complex IMRT radiation fields.

 

OmniPro ImRT
OmniPro I’mRT is an intuitive, user-friendly application software for complete dosimetric verification and QA of IMRT treatment cycles.

It incorporates the latest software technology with extensive and flexible import as well as export functionalities to compare TPS planned date with dose distributions from film exposed in a phantom such as the I’mRT Phantom, or with 2D data acquired with film or electronic 2D devices like I’mRT MatriXX, iViewGT, I’mRT QA or BIS-710.

An easy parameter setup enables fast, real time verification of measured versus planned IMRT treatment cycles. It includes various types of 1D, 2D and 3D visualization techniques like step and shoot or sliding windows, data analysis functions and image processing tools. Visual and mathematical comparisons using modern analysis tools such as the Gamma method are also included.

 

ImRT Phantom
During implementation of IMRT treatments in clinical routine, film dosimetry is used to verify the planned TPS dose versus the measured dose distribution.

The I’mRT Phantom is a water equivalent phantom for multiple film measurements and verification of the absolute dose. The unique modular design allows Universal Body as well as Head and Neck and Stereotactic applications.

 

IMRT Dose Verification Phantom
The IMRT Phantom is designed to provide feedback on complex treatment plans generated using 3D. This Phantom is especially applicable to IMRT and tomotherapy modalities. Multiple thicknesses allow measurements for different body sizes. Both film and ion chambers can be simultaneously irradiated for comparisons with the treatment planning system.

VERIFY PATIENT IMRT TREATMENT PLANS
The anthropomorphic design of the IMRT Dose Verification Phantom mimics human anatomy which assists in set up and treatment for patient dose verification. It is ideal for prostate and head and neck regions, as well as for commissioning respiratory gated protocols because the accuracy of prescribed dose is evaluated and confirmed in simulated patient conditions. The IMRT Dose Verification Phantom is available in Acrylic REF 91230 or Virtual Water™ REF 91235 material.

 